The world’s only CLIA-waived blood-lead analyzer, LeadCare II improves clinical outcomes and is ideal for the physician or pediatric office, health clinic, Point-of-Care Testing, outreach screening programs and veterinary applications. No other system offers the simplicity, accuracy, and immediacy of the LeadCare II.
The LeadCare II analyser offers a fast, accurate and inexpensive way to perform blood-lead level measurements with only 2 drops of blood, right in your office or on-site for immediate results.
The compact and very simple to use LeadCare II system delivers quantitative blood-lead results comparable to those reported by reference laboratories in just 3 minutes, removing all the complications previously associated with blood-lead testing.
Developed in conjunction with the CDC, LeadCare II provides the important information to initiate immediate treatment when necessary or offer peace of mind when not.
The LeadCare II is widely used by paediatricians, family practitioners, public health, and military clinics worldwide.
No more waiting days for expensive lab analysis, or worrying about losing track of a child that needs follow-up care. LeadCare II delivers quantitative lead levels equivalent to those reported by outside laboratories in just three minutes. It improves patient care by providing on-the-spot results, cuts your staffs’ result-tracking and administrative time.
The LeadCare II Analyzer Kit contains the Analyzer and training materials.
Quick Specs
Point-of-care results in just 3 minutes – eliminates multiple visits
Simple to operate – no special training required
Capillary samples (2 drops, 50 µL) – easier for patient, parent, and staff
Accuracy and sensitivity you can count on – comparable to reference lab tests
LeadCare II blood lead analyser ~ Key features
Portable and very simple to use
Results in 3 minutes
Accuracy and precision comparable to reference laboratory
Small sample size
Analyzer Kit contents
LeadCare II Analyzer
AC Adapter
AA Batteries
Quick User Reference Guide
User’s Guide
Instructional video on CD
CDC Blood Collection Video on CD
Test Kit contents (48 tests) - includes lead controls
48 Sensor Strips
48 Treatment Reagent Tubes
50 Heparinized Capillary Tubes/Plungers
50 Transfer Droppers
1 Calibration button
1 Lead Control Level 1(2mL)
1 Lead Control Level 2(2mL)
Heres an excerpt from the US brochure....
At last! There’s a fast, accurate, and inexpensive way to perform
on-the-spot blood-lead measurements at community health
centers, WIC and mobile clinics, health fairs, or home visits.
CLIA-waived LeadCare II removes all the complications formerly
associated with blood-lead testing.
Public health departments and community-outreach programs
are shouldering an ever-increasing burden in the battle against
childhood lead poisoning. Reaching at-risk children even once to
collect a blood sample is challenging enough. Reaching them a
second time to initiate treatment can sometimes be impossible.
No more waiting days for expensive lab results, or spending
precious time trying to locate families for critical follow-up care.
Compact and easy-to-use, LeadCare II delivers quantitative
blood-lead results in just three minutes, so you never have to
worry about losing track of a child that needs treatment.
LeadCare II improves patient care by providing instant results, so
you can provide in one visit important health information on the
dangers of lead, initiate immediate treatment when necessary,
and offer peace of mind when it’s not.
LeadCare II allows you to screen more at-risk children because
it cuts time spent on paper work, tracking and follow up, and
qualifies for reimbursement as a quantitative blood-lead test.
And the cost per test is actually less than you would pay an
outside laboratory, freeing resources so you can establish a
sustainable program to help cover your uninsured population.
Developed with funding from the CDC, LeadCare II is an
improved, waived version of the blood-lead testing system used
by pediatricians, family practitioners, public health and military
clinics worldwide. It is the latest innovation from the name that
has become synonymous with blood-lead measurement – ESA
Biosciences.
LeadCare II blood lead analyser ~ technical
Test method
Electrochemical with disposable sensors
Blood-lead level range
3.3 – 65 ug / dl
Test time
3 minutes
Calibration
Electronic calibration button
CLIA classification
Waived
Certification
CE, UL, CSA
LeadCare II blood lead analyser ~ accessories
Optional Accessory
Seiko Smart Label Printer
Print up to date labels as fast as one second. With 300 dpi resolution, print sharp text, detailed graphics and accurate barcodes on labels up to 2 1/8 inch wide. This printer is is easy to use and install and prints labels in a variety of sizes, materials and colors for only centss per label.
LeadCare II blood lead analyser ~ downloads
Document
Size
download
Leadcare II brochure
250 KB
Leadcare II User Manual
224 KB
Technical Leadcare II product insert
172 KB
These are PDF files, to obtain a free Adobe PDF reader:
LeadCare II blood lead analyser ~ Frequently asked questions
Some of the Frequently asked questions about LeadCare II Blood-Lead Analysis Instrument courtesy Eppendorf AG
LeadCare II blood lead analyser ~ video footage
Some video showing you the LeadCare II Blood-Lead Analysis Instrument in action